		| Spec | Step | Test condition | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| A | B | C | D | E | F | G | H | K | ||
| MIL-STD-883 | Cold | -55 (-10/+0) | -55 (-10/+0) | -65 (-10/+0) | -65 (-10/+0) | -65 (-10/+0) | -65 (-10/+0) | |||
| Hot | 85 (+10/-0) | 125 (+10/-0) | 150 (+10/-0) | 200 (+10/-0) | 300 (+10/-0) | 175 (+10/-0) | ||||
| JESD22-A104 | Cold | -55 (-10/+0) | -55 (-10/+0) | -65 (-10/+0) | -40 (-10/+0) | -55 (-10/+0) | -0 (-10/+0) | |||
| Hot | 85 (+10/-0) | 125 (+10/-0) | 150 (+10/-0) | 125 (+10/-0) | 150 (+10/-0) | 125 (+10/-0) | ||||
| Condition | Reference | Test requirements/cautions | ||||||||
| AEC-Q100 | JEDEC JESD22-A104 and Appendix 3 | Proceed with WBP after TC (After TC completion, perform WBP using 5 samples in one lot: 2 intermediate bonds per corner and 1 intermediate bond per side) | ||||||||
| Grade 0 : -55ºC to +150ºC for 2000 cycles or equivalent. | ||||||||||
| Grade 1 : -55°C to +150oC for 1000 cycles or equivalent. (Note: -65°C to 150°C for 500 cycles is also an allowed test condition due to legacy use with no known lifetime issues. ) | ||||||||||
| Grade 2 : -55ºC to +125ºC for 1000 cycles or equivalent. | ||||||||||
| Grade 3 : -55ºC to +125ºC for 500 cycles or equivalent. | ||||||||||