ADVANCED ANALYSIS / TEST

Autoclave

Autoclave

  • Evaluate the moisture resistance integrity of a sealed solid state device using a moisture condensation or moisture saturated vapor environment.
    A highly accelerated test using pressure, humidity and temperature conditions under condensation to accelerate water penetration through the exterior, along the interface between the protective material (sealing or sealing material) or the exterior protective material and the metal conductor passing through it.

Conditions of progress

Spec Step Test condition
A B C D E F
JESD22-A102 Temperature (Dry Bulb ℃) 121℃/±2
Relative Humidity (%) 100%
Vapor Pressure (psig) 2 ATM(30±1)
Test Time 24 hrs(-0/+2) 48 hrs(-0/+2) 96 hrs(-0/+2) 168 hrs(-0/+2) 240 hrs(-0/+2) 336 hrs(-0/+2)