| 조건 | Reference | 시험 요구/주의사항 |
|---|---|---|
| Preconditioning | JEDEC J-STD-020, JESD22-A113 | AEC-Q100 최소 허용 수준은 JA113에 따른 level 3 (30℃/60% 192hrs) |
| LEVEL | FLOOR LIFE4 | SOAK REQUIREMENTS3 | |||||
|---|---|---|---|---|---|---|---|
| STANDARD | ACCELERATED EQUIVALENT1 | ||||||
| eV 0.40-0.48 |
eV 0.30-0.39 |
CONDITION | |||||
| TIME | CONDITION | TIME(hours) | CONDITION | TIME(hours) | TIME(hours) | ||
| 1 | Unlimited | ≤30 ℃/85% RH |
168 +5/-0 |
85 ℃/85% RH |
NA | NA | NA |
| 2 | 2 year | ≤30 ℃/60% RH |
168 +5/-0 |
85 ℃/60% RH |
NA | NA | NA |
| 2a | 4 weeks | ≤30 ℃/60% RH |
6962 +5/-0 |
30 ℃/60% RH |
120 +1/-0 |
168 +1/-0 |
60 ℃/60% RH |
| 3 | 168 hours | ≤30 ℃/60% RH |
1922 +5/-0 |
30 ℃/60% RH |
40 +1/-0 |
52 +1/-0 |
60 ℃/60% RH |
| 4 | 72 hours | ≤30 ℃/60% RH |
962 +5/-0 |
30 ℃/60% RH |
20 +0.5/-0 |
24 +0.5/-0 |
60 ℃/60% RH |
| 5 | 48 hours | ≤30 ℃/60% RH |
722 +5/-0 |
30 ℃/60% RH |
15 +0.5/-0 |
20 +0.5/-0 |
60 ℃/60% RH |
| 5a | 24 hours | ≤30 ℃/60% RH |
482 +5/-0 |
30 ℃/60% RH |
10 +0.5/-0 |
13 +0.5/-0 |
60 ℃/60% RH |
| 6 | Time on Label(TOL) | ≤30 ℃/60% RH |
TOL | 30 ℃/60% RH |
NA | NA | NA |